Based on system load and time needed by other calibration runs, the time
between dev->mac_work runs can vary quite a bit.
Calculate busy time based on the actual time difference in order to avoid
potentially over-estimating busy time, which could lead to unnecessary tx
blocking.
Signed-off-by: Felix Fietkau <[email protected]>
ED/CCA Tx blocking checks need to be run every 100 ms in order to avoid
triggering too late and keeping tx blocking on for too long
Signed-off-by: Felix Fietkau <[email protected]>
Software encrypted packets can be passed not just through the drv_tx callback,
but also through the intermediate tx queue.
In order to deal with that, move the override to mt76x02_mac_write_txwi and
also take care of filling in the per-packet rate information
Signed-off-by: Felix Fietkau <[email protected]>
Since we implement beconing on USB now, similar interfaces should be
supported for USB as are for MMIO. Tested only on IBSS mode and
AP mode (not enabled due to lack of PS buffering).
Signed-off-by: Stanislaw Gruszka <[email protected]>
Signed-off-by: Felix Fietkau <[email protected]>
Configure beaconing on USB devices without PS buffering support.
Signed-off-by: Stanislaw Gruszka <[email protected]>
Signed-off-by: Felix Fietkau <[email protected]>
Disable BEACON timer during init and configure interrupt registers
only for mmio devices.
Signed-off-by: Stanislaw Gruszka <[email protected]>
Signed-off-by: Felix Fietkau <[email protected]>
BSSID is not strtirct related with beaconing (for example we can have
2 STA vifs) and more related with MAC address, so initaize BSSID when
setting MAC address.
Signed-off-by: Stanislaw Gruszka <[email protected]>
Signed-off-by: Felix Fietkau <[email protected]>
Since we now support mt76x2u feature to allow set mac address
when creating interface in common code we can use it for
mt76x2u.
Signed-off-by: Stanislaw Gruszka <[email protected]>
Signed-off-by: Felix Fietkau <[email protected]>
Use vif_mask to count interfaces to allow to set mac address in HW
if there is only one interface and report error if we create
interface with wrong BSSID resulting in already used index.
Signed-off-by: Stanislaw Gruszka <[email protected]>
Signed-off-by: Felix Fietkau <[email protected]>
Add mt76x0_init_txpower in order to initialize max_power per channel
at device bootstrap. Modify mt76x0_get_tx_power_per_rate and
mt76x0_get_power_info signature in order to compute tx power for
non-operating channels
Signed-off-by: Lorenzo Bianconi <[email protected]>
Initialize target_power variable in mt76x0_phy_set_txpower in order to
report target_power in debugfs
Signed-off-by: Lorenzo Bianconi <[email protected]>
It needs to be unset instead of set
Fixes: 23405236460b9 ("mt76: fix transmission of encrypted management frames")
Cc: [email protected]
Signed-off-by: Felix Fietkau <[email protected]>
Since ccmp_pn is u8 *, the second half needs to start at array index 4
instead of 0. Fixes a connection stall after a certain amount of traffic
Fixes: 23405236460b9 ("mt76: fix transmission of encrypted management frames")
Cc: [email protected]
Signed-off-by: Felix Fietkau <[email protected]>
Set the per-chain signal value for chain 0 and simplify the code
(no need for a loop for just one extra chain)
Signed-off-by: Felix Fietkau <[email protected]>
Remove bogus check for MT_PACKET_ID_NO_ACK in mt76_tx_status_skb_get, which
is already handled in callers and turns timeout calls into no-ops
Do not clean up pending status items on reordering of tx status information
if the timeout is not reached yet
Signed-off-by: Felix Fietkau <[email protected]>
For some reason the BMC queue flush does not work properly if packets were
queued for a BSS0_n interface (secondary vif).
Work around this issue by using the DMA scheduler to filter the queue before
issueing the BMC queue flush.
Signed-off-by: Felix Fietkau <[email protected]>
Take into account device rx stream in mt76x02_mac_process_rate
in order to not report wrong number of rx spatial stream to mac80211.
The issue has been reported on mt76x0 device which is 1x1:1 however
the hw sometimes reports rx nss equal to 2
Signed-off-by: Lorenzo Bianconi <[email protected]>
Signed-off-by: Felix Fietkau <[email protected]>
Sync CCK values with reference driver.
Use OFDM values obtained from the hardware reset value
Stop tx/rx on change only using the ARB_SCR register
Signed-off-by: Felix Fietkau <[email protected]>
The hardware needs to be notified of peers using dynamic SMPS mode
Fixes using dual-stream rates on some clients (e.g. Intel)
Signed-off-by: Felix Fietkau <[email protected]>
Clear pending PSE request bit in order to avoid having it trigger by the
firmware at a bad point in time.
Only clear AC queue stuck bits if the PSE reset succeeded
Signed-off-by: Felix Fietkau <[email protected]>
The hardware cannot report accurate tx A-MPDU length information, so tell rate
control to ignore it. Improves tx rate selection
Signed-off-by: Felix Fietkau <[email protected]>
The hardware does not deal with multiple WCID entries for the same station
properly. Set IEEE80211_HW_NEEDS_UNIQUE_STA_ADDR to avoid those cases
Signed-off-by: Felix Fietkau <[email protected]>
Reporting A-MPDU length from txs does not work, because only completed
subframes are reported. Trying to aggregate tx status report for one
completed A-MPDU does not work, because individual subframe retries can
be different.
Do not report A-MPDU length > 1 and pass individual subframe tx status
information to mac80211 to fix rate control errors
Signed-off-by: Felix Fietkau <[email protected]>