When doing a custom bootstrap the configured value of max_connections could be smaller than the actual value stored in the pg_contol. As a workaround Patroni already did an adjustment of such parameters. Unfortunately, it doesn't cover the case when the parameter value was increased even higher during the WAL replay. That was causing postgres to stop.
The hot_standby=off disable connections to the instance, but allows postgres to run with parameter values smaller than required.
The hot_standby=off doesn't affect the running primary. When the recovery finishes and postgres promotes it starts accepting connections as usual. If the node will be demoted, Patroni will stop postgres and start it up as replica with hot_standby=on.
Upon the start of Patroni and Postgres make sure that unix_socket_directories and stats_temp_directory exist or try to create them. Patroni will exit if failed to create them.
Close https://github.com/zalando/patroni/issues/863
That required a refactoring of `Config` and `Patroni` classes. Now one has to explicitely create the instance of `Config` before creating `Patroni`.
The Config file can optionally call the validate function.