mirror of
https://github.com/outbackdingo/mt76.git
synced 2026-10-24 13:26:48 +00:00
9b97e0f2a5564c3d62337bff0f41c50862ea850f
If we are associated and scanning is performed, sw_scan_complete callback
is done after we get back to operating channel, so we do not perform
queue cal work. Fix this queue cal work from sw_scan_complete().
On mt76x0 we have to restore gain in MT_BBP(AGC, 8) register after
scanning, as it was multiple times modified by channel switch code.
So queue cal work without any delay to set AGC gain value.
Similar like in mt76x2 init AGC gain only when set operating channel
and just check before queuing cal work in sw_scan_complete() if
initialization was already done.
Fixes: bbd10586f0df ("mt76x0: phy: do not run calibration during channel switch")
Signed-off-by: Stanislaw Gruszka <[email protected]>
Description
mac80211 driver for MediaTek MT76x0e, MT76x2e, MT7603, MT7615, MT7628 and MT7688