wifi: mt76: mt7996: adjust timeout value for boot-up calibration commands

Align the vendor driver by adjusting the timeout values for the
MCU_UNI_CMD_EFUSE_CTRL and MCU_UNI_CMD_EXT_EEPROM_CTRL commands.
Without this adjustment, false positive command timeout errors may occur,
especially on some iPA variants.

Signed-off-by: Rex Lu <[email protected]>
Signed-off-by: Shayne Chen <[email protected]>
Link: https://patch.msgid.link/[email protected]
Signed-off-by: Felix Fietkau <[email protected]>
This commit is contained in:
Rex Lu
2026-03-14 08:32:20 +00:00
committed by Felix Fietkau
parent 9b6cc2ba66
commit 4edbdf38c6
+2 -1
View File
@@ -278,7 +278,8 @@ mt7996_mcu_set_timeout(struct mt76_dev *mdev, int cmd)
mdev->mcu.timeout = 2 * HZ;
return;
case MCU_UNI_CMD_EFUSE_CTRL:
mdev->mcu.timeout = 20 * HZ;
case MCU_UNI_CMD_EXT_EEPROM_CTRL:
mdev->mcu.timeout = 30 * HZ;
return;
default:
break;