T
Alexander KukushkinandGitHub bfbc4860d5 PoC: Patroni on pure RAFT (#375)
* new node can join the cluster dynamically and become a part of consensus
 * it is also possible to join only Patroni cluster (without adding the node to the raft), just comment or remove `raft.self_addr` for that
 * when the node joins the cluster it is using values from `raft.partner_addrs` only for initial discovery.
* It is possible to run Patroni and Postgres on two nodes plus one node with `patroni_raft_controller` (without Patroni and Postgres). In such setup one can temporarily lose one node without affecting the primary.
2020-07-29 15:34:44 +02:00

105 lines
2.9 KiB
Python

import abc
import os
import signal
import six
import sys
from threading import Lock
@six.add_metaclass(abc.ABCMeta)
class AbstractPatroniDaemon(object):
def __init__(self, config):
from patroni.log import PatroniLogger
self.setup_signal_handlers()
self.logger = PatroniLogger()
self.config = config
AbstractPatroniDaemon.reload_config(self, local=True)
def sighup_handler(self, *args):
self._received_sighup = True
def sigterm_handler(self, *args):
with self._sigterm_lock:
if not self._received_sigterm:
self._received_sigterm = True
sys.exit()
def setup_signal_handlers(self):
self._received_sighup = False
self._sigterm_lock = Lock()
self._received_sigterm = False
if os.name != 'nt':
signal.signal(signal.SIGHUP, self.sighup_handler)
signal.signal(signal.SIGTERM, self.sigterm_handler)
@property
def received_sigterm(self):
with self._sigterm_lock:
return self._received_sigterm
def reload_config(self, sighup=False, local=False):
if local:
self.logger.reload_config(self.config.get('log', {}))
@abc.abstractmethod
def _run_cycle(self):
"""_run_cycle"""
def run(self):
self.logger.start()
while not self.received_sigterm:
if self._received_sighup:
self._received_sighup = False
self.reload_config(True, self.config.reload_local_configuration())
self._run_cycle()
@abc.abstractmethod
def _shutdown(self):
"""_shutdown"""
def shutdown(self):
with self._sigterm_lock:
self._received_sigterm = True
self._shutdown()
self.logger.shutdown()
def abstract_main(cls, validator=None):
import argparse
from .config import Config, ConfigParseError
from .version import __version__
parser = argparse.ArgumentParser()
parser.add_argument('--version', action='version', version='%(prog)s {0}'.format(__version__))
if validator:
parser.add_argument('--validate-config', action='store_true', help='Run config validator and exit')
parser.add_argument('configfile', nargs='?', default='',
help='Patroni may also read the configuration from the {0} environment variable'
.format(Config.PATRONI_CONFIG_VARIABLE))
args = parser.parse_args()
try:
if validator and args.validate_config:
Config(args.configfile, validator=validator)
sys.exit()
config = Config(args.configfile)
except ConfigParseError as e:
if e.value:
print(e.value)
parser.print_help()
sys.exit(1)
controller = cls(config)
try:
controller.run()
except KeyboardInterrupt:
pass
finally: