When disassociating and clearing the BSSID of a repeater entry used by a client mode interface, the corresponding MAC address entry can get lost too, causing the client interface to not be able to associate anymore. Fix this by also refreshing the MAC address when setting the BSSID Signed-off-by: Felix Fietkau <[email protected]>