Files
mt76/mt7915
David BauerandFelix Fietkau 0534761b76 wifi: mt76: mt7915: mcu: lower default timeout
The default timeout set in mt76_connac2_mcu_fill_message of 20 seconds
leads to excessive stalling in case messages are lost.

Testing showed that a smaller timeout of 5 seconds is sufficient in
normal operation.

Signed-off-by: David Bauer <[email protected]>
Link: https://patch.msgid.link/[email protected]
Signed-off-by: Felix Fietkau <[email protected]>
2025-06-01 22:03:37 +02:00
..
2024-07-12 17:15:04 +02:00